Start with the room’s floor area. ENERGY STAR’s sizing table turns square feet into BTU per hour, then adjusts for sun, people and a kitchen. This page gives the table, three worked rooms, and the two adjustments the table leaves out.

The table

ENERGY STAR publishes this table for room air conditioners. It assumes an 8 foot ceiling and gives a cooling capacity. It is a starting point for a mini split, not a maker’s rating.

Room area (sq ft) BTU per hour
100 up to 150 5,000
150 up to 250 6,000
250 up to 300 7,000
300 up to 350 8,000
350 up to 400 9,000
400 up to 450 10,000
450 up to 550 12,000
550 up to 700 14,000
700 up to 1,000 18,000
1,000 up to 1,200 21,000
1,200 up to 1,400 23,000
1,400 up to 1,500 24,000
1,500 up to 2,000 30,000
2,000 up to 2,500 34,000

“Up to” means the top of a row belongs to the next row, so a 150 sq ft room reads 6,000.

The adjustments

ENERGY STAR makes four:

The tool takes the percentage first, then adds the fixed amounts, because ENERGY STAR does not give an order.

ENERGY STAR gives no number for ceilings above 8 feet or for climate. Senville, a mini split maker, publishes both on its sizing guide: add 10 percent for every 2 feet of ceiling over 8 feet, 15 percent in a hot climate (over 90°F) and 20 percent in a cold one (below 20°F, with a unit rated for low temperatures). The tool applies them in whole 2 foot steps and labels them as Senville’s. Senville also lists 15 to 20 percent more for poor insulation. The tool has no insulation setting, so add that yourself if it fits your room.

Three rooms

Run your own room

Mini splits are sold in set sizes

Start with the smallest size that reaches your number. For 12,200 BTU that is 18,000, and for 22,000 it is 24,000. The two lines we checked come in 9,000, 12,000, 18,000, 24,000, 30,000 and 36,000 BTU, and not every line has every one. One of the models we checked rates its “24,000” size at 23,000 BTU of cooling. The tool compares each model’s rated cooling to your number, not its name.

Bigger is not safer

ENERGY STAR warns that a unit that is too large cools the air before it removes the humidity, and the room ends up clammy. Some mini splits can run well below their rated size. The Pioneer Diamante Pro 12,000 BTU models list a cooling range of 3,400 to 13,000 BTU. The tool shows the range where the maker gives one.

When this table is not enough

The table is for one room. For a whole house, or a room with unusual glass, insulation or a long duct run, ask a contractor for a load calculation. Heating is a separate question in cold places: read the unit’s heating output at 5°F on the maker’s page, not its nominal size. The Pioneer 12,000 BTU Diamante Pro lists 9,000 BTU of heating at 5°F.

Mini Split Fit reads each maker’s documents, and says “check” when a maker does not give a number.