What size mini split do you need?
Start with the room’s floor area. ENERGY STAR’s sizing table turns square feet into BTU per hour, then adjusts for sun, people and a kitchen. This page gives the table, three worked rooms, and the two adjustments the table leaves out.
The table
ENERGY STAR publishes this table for room air conditioners. It assumes an 8 foot ceiling and gives a cooling capacity. It is a starting point for a mini split, not a maker’s rating.
| Room area (sq ft) | BTU per hour |
|---|---|
| 100 up to 150 | 5,000 |
| 150 up to 250 | 6,000 |
| 250 up to 300 | 7,000 |
| 300 up to 350 | 8,000 |
| 350 up to 400 | 9,000 |
| 400 up to 450 | 10,000 |
| 450 up to 550 | 12,000 |
| 550 up to 700 | 14,000 |
| 700 up to 1,000 | 18,000 |
| 1,000 up to 1,200 | 21,000 |
| 1,200 up to 1,400 | 23,000 |
| 1,400 up to 1,500 | 24,000 |
| 1,500 up to 2,000 | 30,000 |
| 2,000 up to 2,500 | 34,000 |
“Up to” means the top of a row belongs to the next row, so a 150 sq ft room reads 6,000.
The adjustments
ENERGY STAR makes four:
- A heavily shaded room: reduce the figure by 10 percent.
- A very sunny room: increase it by 10 percent.
- More than two people in the room: add 600 BTU for each extra person.
- A kitchen: add 4,000 BTU.
The tool takes the percentage first, then adds the fixed amounts, because ENERGY STAR does not give an order.
ENERGY STAR gives no number for ceilings above 8 feet or for climate. Senville, a mini split maker, publishes both on its sizing guide: add 10 percent for every 2 feet of ceiling over 8 feet, 15 percent in a hot climate (over 90°F) and 20 percent in a cold one (below 20°F, with a unit rated for low temperatures). The tool applies them in whole 2 foot steps and labels them as Senville’s. Senville also lists 15 to 20 percent more for poor insulation. The tool has no insulation setting, so add that yourself if it fits your room.
Three rooms
- A 14 by 16 ft bedroom, 224 sq ft. The table row is 6,000 BTU. Nothing is adjusted, so the answer is 6,000, and the smallest size to compare is 9,000.
- A 20 by 20 ft living room with a lot of sun and four people, 400 sq ft. The table row is 10,000. Very sunny adds 10 percent, 1,000. Two extra people add 1,200. The answer is 12,200 BTU, which is just over a 12,000 BTU unit.
- A 25 by 30 ft open kitchen and dining room, 750 sq ft. The table row is 18,000. The kitchen adds 4,000. The answer is 22,000 BTU.
Mini splits are sold in set sizes
Start with the smallest size that reaches your number. For 12,200 BTU that is 18,000, and for 22,000 it is 24,000. The two lines we checked come in 9,000, 12,000, 18,000, 24,000, 30,000 and 36,000 BTU, and not every line has every one. One of the models we checked rates its “24,000” size at 23,000 BTU of cooling. The tool compares each model’s rated cooling to your number, not its name.
Bigger is not safer
ENERGY STAR warns that a unit that is too large cools the air before it removes the humidity, and the room ends up clammy. Some mini splits can run well below their rated size. The Pioneer Diamante Pro 12,000 BTU models list a cooling range of 3,400 to 13,000 BTU. The tool shows the range where the maker gives one.
When this table is not enough
The table is for one room. For a whole house, or a room with unusual glass, insulation or a long duct run, ask a contractor for a load calculation. Heating is a separate question in cold places: read the unit’s heating output at 5°F on the maker’s page, not its nominal size. The Pioneer 12,000 BTU Diamante Pro lists 9,000 BTU of heating at 5°F.
Mini Split Fit reads each maker’s documents, and says “check” when a maker does not give a number.
Facts read on each maker’s own documents on 19 November 2026.